MANIFOLD
MOUNT SWITCHES
Most
Airtrol Components' pressure and vacuum switches are available
in manifold mount configurations. Figure 1 shows the recommended
manifold detail. Attention must be paid to the tolerance and surface
finish of the .379 ID. Two EPDM 75 durometer O-rings are supplied
with each unit. Two O-rings are recommended in case of surface
imperfections, damage to an O-ring during assembly, etc. The O-rings
must be lubricated with silicone grease during assembly. This
not only eases the assembly procedure, it also enhances the sealing
characteristics of the O-ring, especially in vacuum applications.
Typically,
#4-40 x 5/8 SHCS are used to mount the switch to the manifold.
Avoid overtightening the screws during assembly. "Threadlock"
compounds should be avoided, as most will attack the polysulfone
switch body.
For
further information, contact an Airtrol Applications Engineer
at 1-800-762-0758.