U.S.
Patent No. 5,358,004
The R-800 series regulators offer high performance in a compact
size. 1/8-27 NPT ports allow the use of a wide range of fittings
for design flexibility.
FEATURES:
Twenty turn hysteresis free adjustment allows pressure settings
to 1" WC resolution.
Four
adjusting styles allow maximum design flexibility. The non-rising
stem is available with an attractive knob, or plain, allowing installation
of OEM knobs. Also available is a flush adjusting shaft, for applications
where pressure settings are changed less frequently. Factory pre-set
"tamperproof" models are also available. (See drawings)
Mounting
options include panel mount, through a 9/16" hole (nut included),
and base mount, through 4 holes 0.125" dia. (See drawings)
Plastic
construction - corrosion resistant wetted materials.
High
accuracy - Low effect of supply variation on output.
Low
cost - Perfect for OEM applications.
|
|
|
Applications:
Medical
Equipment
- Oxygen Concentrators
- Ventilator / Respirators
- Nebulizers
Air Bearings
HVAC Systems
Custom Machinery
Robotics
Options
Oxygen Clean
Factory Pre-set
|
 |
| REGULATOR
TYPE |
Constant
Bleed, Relieving
|
 |
| WETTED
MATERIALS |
Polysulfone,
Buna-N, EPDM, Acetal, Polyurethane, Stainless steel |
 |
| SUPPLY
CONSUMPTION |
<
9 SCIM (150 cc/min) @ 30 PSI (207 kPa) supply
< 21 SCIM (350 cc/min) @ 100 PSI (689 kPa) supply |
 |
| MAX
SUPPLY |
150
PSI (1.03 MPa) |
 |
| TEMPERATURE
RANGE |
40°
- 150° F (4° - 66° C) |
 |
| EFFECT
OF SUPPLY VARIATION |
<
0.05 PSI (0.35 KPa) per 10 PSI (68.9 kPa) supply change when
dead-ended |
 |
| REPEATABILITY |
<
+/- 0.1 PSI (0.69 kPa) when supply is removed and re-applied
|
 |
| SENSITIVITY |
1"
H2O (0.25 kPa) |
 |
| MAXIMUM
FLOW |
2.5
cu.ft./min. (70 LPM) |
 |
| RELIEF
CAPACITY |
0.5
cu.ft./min. (14 LPM) with outlet 5 PSI (34.5 kPa) above set-point
|
 |
| RECOMMENDED
FILTRATION |
5
micron |
 |
| REGULATOR
TYPE |
|
| Note:
R-810 series regulators are not recommended for dead-end, no
flow applications. A downstream relief of at least 20 cc/min
is recommended. |
 |
| REPEATABILITY |
<
+/- 0.25 PSI (1.72 kPa) when supply is removed and re-applied
|
 |
| EFFECT
OF SUPPLY VARIATION |
<
0.1 PSI (0.69 kPa) Per 5 PSI (34.5 kPa) supply change |
 |
All
other specifications remain the same as the R-800 Series
| REGULATOR
TYPE |
Non-bleed,
relieving
|
 |
| SUPPLY
CONSUMPTION (see note) |
<
0.3 SCIM (5 cc/min.) |
 |
| REPEATABILITY |
<
+/- 0.25 PSI (1.72 kPa) when supply is removed and re-applied
|
 |
| EFFECT
OF SUPPLY VARIATION |
<
0.1 PSI (0.69 kPa) per 5 PSI (34.5 kPa) supply change |
 |
| SENSITIVITY |
2"
H2O (0.5 kPa) |
 |
All
other specifications remain the same as the R-800 Series
Note:
R-820 series regulators have "near zero" bleed to
atmosphere under normal operating conditions. Should any overshoot,
or downstream pressure increases occur, the unit will relieve
only what is necessary to stabilize the pressure setting.
Important: Proper filtration is a must to maintain correct
operation of the R-820 Series. Airtrol Components Inc. cannot
guarantee perfect "non-bleed" operation under any
circumstances. Consult with an Airtrol Application Engineer
for more information. |
|
 |
| R-800-XX-W/K |
Precision
regulator with adjusting knob |
| R-800-XX-W/S |
Precision
regulator with 1/4" adjusting shaft |
| R-800-XX-W/OS |
Precision
regulator with slotted adjusting shaft |
| R-801-XX |
Factory
pre-set regulator |
| R-810-XX-W/K |
Non-bleed,
non-relieving with adjusting knob |
| R-810-XX-W/S |
Non-bleed,
non-relieving with 1/4" adjusting shaft |
| R-810-XX-W/OS |
Non-bleed,
non-relieving with slotted adjusting shaft |
| R-811-XX |
Non-bleed,
non-relieving, pre-set regulator |
| R-820-XX-W/K |
Non-bleed,
relieving with adjusting knob |
| R-820-XX-W/S |
Non-bleed,
relieving with 1/4" adjusting shaft |
| R-820-XX-W/OS |
Non-bleed,
relieving with slotted adjusting shaft |
| R-821-XX |
Non-bleed,
relieving, pre-set regulator |
|
|
 |