The SDU-5000 series offers unique and practical method of controlling
pressure or vacuum electronically. This is accomplished by interfacing
a stepping motor and gear box to a modified 800 or 900 series subminiature
regulators. A calibration report included with every unit provides
a detailed test data including a scale factor that corresponds to
a slope that will yield a open loop accuracy including linearity,
repeatability and hysteresis, of < +/- 3% FS. The unit can also
be interfaced with Airtrols 4103/4104 series spring biased comparators.
Also available are the EVB-5000 Evaluation board, and SDB-5000 Interface
board.
|
|
|
|
 |
| ACCURACY |
<
+/- 3% FS BFSL including linearity, repeatability and hysteresis
|
 |
| DIMENSIONS |
2.875"
x 2.125" x 3.5" (73 x 54 x 89 mm) |
 |
| WEIGHT |
8
oz (227 g) |
 |
| MOTOR
TYPE |
15°
bi-polar stepping |
 |
| COIL
RESISTANCE |
36
Ohms/Phase |
 |
| RECOMMENDED
CURRENT |
<
170 mA / coil for 100% duty cycle |
 |
| GEAR
RATIO |
20.83:1 |
 |
| TYPICAL
STEP RATE |
200
steps / sec |
 |
| REGULATOR
TYPE |
Constant
Bleed, Relieving
|
 |
| WETTED
MATERIALS |
Polysulfone,
Buna-N, EPDM, Acetal, Polyurethane, Stainless steel |
 |
| SUPPLY
CONSUMPTION |
<
9 SCIM (150 cc/min) @ 30 PSI (207 kPa) supply
< 21 SCIM (350 cc/min) @ 100 PSI (689 kPa) supply |
 |
| MAX
SUPPLY |
150
PSI (1.03 MPa) |
 |
| TEMPERATURE
RANGE |
40°
- 150° F (4° - 66° C) |
 |
| EFFECT
OF SUPPLY VARIATION |
<
0.07 PSI (0.48 KPa) per 10 PSI (68.9 kPa) supply change when
dead-ended |
 |
| REPEATABILITY |
<
+/- 0.1 PSI (0.69 kPa) when supply is removed and re-applied
|
 |
| SENSITIVITY |
1"
H2O (0.25 kPa) |
 |
| MAXIMUM
FLOW |
2.3
cu.ft./min. (65 LPM) |
 |
| RELIEF
CAPACITY |
0.5
cu.ft./min. (14 LPM) with outlet
5 PSI (34.5 kPa) above set-point |
 |
| RECOMMENDED
FILTRATION |
5
micron |
 |
|
|
|
The
SDU-5000 can be driven using a variety of drive methods,
including constant voltage, L/R, constant current (chopper)
and bi-level (two voltage) drives. Airtrol's SDB-5000 series
L/R drive board offers a simple an inexpensive interface
to any digital signal source. For more demanding applications,
a bi-level or chopper drive is recommended. A bi-level drive
is also recommended for high speed applications where a
frequency ramp is not being used to accelerate the motor.
This will allow pressure changes to be made at an increased
power setting, after which the power can be reduced to an
"idle" setting to prevent over heating. The figure to the
right shows recommended fixed frequencies for various current
levels. Note that the current levels above 170 mA/coil,
a duty cycle must be observed (based on a 10 min. cycle).
The
truth table shown to the right defines the step sequence/direction
relationship for the SDU-5000 Stepper Drive Unit.
|
 |
|
 |
SDU-5000/SDR-800/10
SDU-5000/SDR-800/30
SDU-5000/SDR-800/60
SDU-5000/SDR-800/90
SDU-5000/SDR-900/10
SDU-5000/SDR-900/30
SDU-5000/SDR-900/60
SDU-5000/SDR-900/90
SDU-5000/SDV-800/10
SDU-5000/SDV-800/30
SDU-5000/SDV-900/10
SDU-5000/SDV-900/30 |
Stepper
Driven Regulator, 0.7-10 PSI, 1/8"NPT Ports
Stepper Driven Regulator, 0.7-30 PSI, 1/8"NPT Ports
Stepper Driven Regulator, 0.7-60 PSI, 1/8"NPT Ports
Stepper Driven Regulator, 0.7-90 PSI, 1/8"NPT Ports
Stepper Driven Regulator, 0.7-10 PSI, 10-32 Ports
Stepper Driven Regulator, 0.7-30 PSI, 10-32 Ports
Stepper Driven Regulator, 0.7-60 PSI, 10-32 Ports
Stepper Driven Regulator, 0.7-90 PSI, 10-32 Ports
Stepper Driven Regulator, 0.7-10" Hg Vac, 1/8"NPT
Ports
Stepper Driven Regulator, 0.7-30" Hg Vac, 1/8"NPT
Ports
Stepper Driven Regulator, 0.7-10" Hg Vac, 10-32 Ports
Stepper Driven Regulator, 0.7-30" Hg Vac, 10-32 Ports |
|
|
 |